T3 Short Dental Implant

Implant Treatment Options for Vertical Height Deficiencies

The T3 Short Dental Implant’s length and features are designed to provide an implant treatment option in some challenging clinical cases where the bone height is insufficient for standard length dental implants.

Features

  • T3 Surface: Blasted and acid-etched implant surface with an average roughness of 1.4 µm along the full length of the implant.
  • Initial Bone-to-Implant Contact (IBIC): The dimensions of the surgical instrumentation and the T3 Short Implant provide a tight implant-to-osteotomy fit, to assist with primary stability.
  • Implant/Abutment Clamping Force: Proprietary* Gold-Tite Surface lubrication allows the screw to rotate further, increasing clamping force and maximizing abutment stability.
  • Platform Switching: Platform switching medializes the implant/abutment junction (IAJ) redirecting the reformation of the biologic width, thus helping to maintain bone levels.

Benefits

  • Enhanced Primary Stability: Achieved through increased Initial Bone-to-Implant Contact (IBIC) resulting from the precise fit between the implant and the osteotomy, supported by specialized surgical tools
  • Abutment Stability: Ensures increased abutment stability through enhanced clamping force
  • Biological Preservation: Supports the maintenance of alveolar bone levels by biologically protecting the implant-abutment interface
  • Avoidance of Regenerative Techniques: Allows for implant placement without the need for time-consuming and complex bone regeneration procedures
  • Reduced Patient Burden: Minimizes both treatment costs and surgical morbidity, providing a viable solution where anatomical limitations prevent invasive procedures

T3 Short Dental Implant in reduce bone height posterios mandible

T3 Short Dental Implant Drilling & Placement Protocol

Resources

T3 Short Implant Brochure Final Secured

Certain Implant System Product Catalog Final Secured

External Hex Ordering Info Brochure

Clinical Case T3 Short

T3 Short Implant Quick Reference Quide Final Secured

T3 Short Implant Surgical Manual Final Secured

T3 Short Implant System Surgical Kit Assembly Final Secured

1  Gubbi P†, Towse R†. Quantitative and Qualitative Characterization of Various Dental Implant Surfaces. Poster Presentation: European Association for Osseointegration, 20th Annual Meeting; October 2012; Copenhagen, Denmark. To view the poster, please visit www.biomet3i.com/pdf/Posters/Poster_421_EAO_Final.pdf

2  Meltzer AM‡. Primary stability and initial bone-to-implant contact: The effects on immediate placement and restoration of dental implants. J Implant Reconstr Dent. 2009;1(1):35-41. 3  Byrne D, Jacobs S, O’Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont. 2006 May–Jun;15(3):164-171.

4  Boitel N, Andreoni C, Grunder U‡, Naef R, Meyenberg K‡. A Three Year Prospective, Multicenter, Randomized-Controlled Study Evaluating Platform-Switching for the Preservation of Peri-implant Bone Levels. Academy of Osseointegration, 26th Annual Meeting: 2011 March 3-5; Washington DC. To view the poster, please visit www.biomet3i.com/Resource%20Center/Publications%20of%20Interest/Platform_Switching_for_the_Preservation_of%20Peri_Implant%20Bone%20Levels.pdf. A Biomet 3i sponsored study.

†  The authors conducted this research while employed at Biomet 3i.

‡  Drs Grunder, Meltzer and Meyenberg have or had, financial relationships with Zimmer Biomet Dental resulting from speaking engagements, consulting engagements and other retained services.

* Pre-clinical studies are not necessarily indicative of clinical results.

**  Placement of a smaller diameter restorative component than the diameter of the implant seating surface.

†  Dr. Block, Dr. Goené, Dr. Grunder, Dr. Lazzara, Dr. Makigusa, Dr. Meltzer, Dr. Méndez, Dr.

Meyenberg, Dr. Nevins, Dr. Östman, Dr. Rodríguez, Dr. Segalá, Dr. Scutellá, Dr. Tarnow, Dr. Testori and Dr. Vela have financial relationships with Biomet 3i, LLC resulting from speaking engagements, consulting engagements and other retained services.

††  Dr. Gubbi, Mr. Suttin and Mr. Towse contributed to the above research while employed by Biomet 3i.

References 6–10 discuss the Tapered Implant macrodesign, which is incorporated into the T3 Implant. References 10–13 discuss the Osseotite and/or NanoTite Implants’ dual acid-etched or DCD technology, which is incorporated into the T3 Implant. References 20–22 discuss PREVAIL® Implants with an integrated platform switching design, which is also incorporated into the T3 Implant.