GenTek®

Genuine Restorative Components

Efficient. Flexible. Genuine.

GenTek restorative components support digitally driven CAD/CAM restorations for ZimVie Implant Systems

Premium implants deserve premium prosthetic components. For long-term clinical success, it is essential that the interface between the implant and abutment are designed to work together. This is required to ensure a robust and stable interface that delivers the long-term aesthetics and function that patients demand.

GenTek Ti-Bases with Standard Post

  • o Precise Connection: A titanium connection ensures a precise fit with the implant
  • o Height Flexibility: They feature a 4.7 mm post height with an integrated cutting groove at 4.0 mm, allowing for precise adjustment to each individual clinical case
  • o CAD/CAM Compatibility: Ti-Bases are designed to be compatible with Sirona CEREC blocks for CEREC Chairside Milling and in-lab CAD/CAM solutions
  • o Wide Range of Applications: Suitable for single-unit, multi-unit, and full-arch restorations via digital workflows
  • GenTek Angulated Screw Channel Ti-Bases o Broad Compatibility: GenTek Restorative Components are available for ZimVie Implant Systems: • TSX® • TSV® • T3® PRO • Certain® • Eztetic® o Access to Restricted Spaces: Ti-Bases with angled screw channel provides access for ZimVie Implant systems, with multiple collar heights o Efficiency and Flexibility: Achieve efficiency to your CAD/CAM restoration workflow with a Ti-Base that provides flexibility of channel angulation, collar heights, and adjustable post height options o Proven Performance: A Ti-Base that provides the performance you expect through ZimVie proven Friction-Fit™ and SureSeal™ Technologies when mated with a ZimVie Implant
  • GenTek® ASC Ti-Bases & Encode® Emergence Healing Abutments o Angulated Screw Channel Ti-Bases with variable collar heights for final custom restoration are designed to mimic the profile radius of Encode Emergence healing abutments o Encode Technology eliminates the need to swap the healing abutment for an impression coping or scanbody, while delivering soft-tissue healing with a natural emergence profile o The compatible Angulated Screw Channel Ti-Bases can be designed to match the patient’s anatomy using the CAD libraries, thereby producing a natural emergence profile through the soft-tissue

GenTek Angulated Screw Channel Ti-Bases

  • o Broad Compatibility: GenTek Restorative Components are available for ZimVie Implant Systems: • TSX® • TSV® • T3® PRO • Certain® • Eztetic®
  • o Access to Restricted Spaces: Ti-Bases with angled screw channel provides access for ZimVie Implant systems, with multiple collar heights
  • o Efficiency and Flexibility: Achieve efficiency to your CAD/CAM restoration workflow with a Ti-Base that provides flexibility of channel angulation, collar heights, and adjustable post height options
  • o Proven Performance: A Ti-Base that provides the performance you expect through ZimVie proven Friction-Fit™ and SureSeal™ Technologies when mated with a ZimVie Implant

GenTek® ASC Ti-Bases & Encode® Emergence Healing Abutments

  • o Angulated Screw Channel Ti-Bases with variable collar heights for final custom restoration are designed to mimic the profile radius of Encode Emergence healing abutments
  • o Encode Technology eliminates the need to swap the healing abutment for an impression coping or scanbody, while delivering soft-tissue healing with a natural emergence profile
  • o The compatible Angulated Screw Channel Ti-Bases can be designed to match the patient’s anatomy using the CAD libraries, thereby producing a natural emergence profile through the soft-tissue

GenTek® Ti-Bases με Standard Post

  • Reliability: The use of genuine ZimVie components guarantees the longevity and stability of the prosthetic restoration
  • Clinical Freedom: The ability to cut the post at the 4.0 mm groove offers the dentist and technician the flexibility to adjust the height according to the available interproximal space
  • Optimized Digital Workflow: Compatibility with the CEREC system reduces milling time and increases the precision of the final restoration

GenTek® Angulated Screw Channel Ti-Bases

  • Ease of Placement: Insert the screw into the restoration before placing it in the patient’s mouth for a more efficient transfer procedure
  • Simplified Removal Process: No abutment removal tool is required to disengage the Ti-Base during the removal process
  • Maintaining Cutting-Edge Technology: The new design retains our company’s Friction-Fit™ technology in the ASC Ti-Bases

GenTek® Scan Bodies

A perfect restorative design starts with a perfect scan in every CAD/CAM restoration. GenTek Scan Bodies lay the foundation for a highly precise digitization of the implant position, whether acquired with an intraoral scanner or a desktop scanner.

  • Precise Fit: A titanium connection ensures a precise fit with the implant
  • Slim Asymmetric Design: A slim asymmetric design to fit in narrow interproximal spaces that does not exceed the implant platform.
  • Dual Functionality: Dual functioning for intraoral and desktop scanning
  • High-Tech Material: The body is constructed of PEEK material to provide a favorable surface for optical scanners
  • Usage Recommendation: The Zfx Torque Wrench is recommended for tightening the GenTek Scan Bodies when used for scanning in the lab. It features a torque control mechanism that ensures proper tightening torque on the lab mode

GenTek® Low Profile εξαρτήματα αποκατάστασης

GenTek Digital Analogs provide an accurate fit for design of the definitive restoration.

  • Product Range Contents: GenTek Low Profile restorative components include a coping, scan body and analog
  • Indications: Indicated for use for single-unit, multi-unit, and full-arch restorations utilizing digital workflows
  • Compatibility: Ti-Bases are designed to be compatible with Sirona CEREC blocks for CEREC Chairside Milling and in-lab CAD/CAM solutions
  • Technical Specifications:7mm post height with a cutting grove at 4.0mm

GenTek® Titanium Pre-Milled Abutment Blanks/ Blocks τιτανίου για εξατομικευμένες εργασίες

GenTek Titanium Pre-Milled Abutment Blanks enable the fabrication of customized titanium abutments without compromising connection quality and restoration performance

  • Processing flexibility:Compatible with a variety of ZimVie Pre-Abutment Blank Holders and all milling machines that work with Medentika PreFace® Abutment Holders

GenTek branded to indicate a genuine ZimVie connection

GenTek® Genuine Restorative Components

Fixation Screw Technique Guide for GenTek® ASC Ti-Bases

Resources

Gentek Cerec Compatible Ti-Bases Datasheet Final Secured

Gentek Genuine Restorative Components Brochure

Restorative Digital Workflolw

Gentek Catalogue Final Secured

Gentek Certain Product Catalog Final Secured

Gentek TSV Product Catalog Final Secured

Gentek Tools Checklist Certain Final Secured

Gentek Tools Checklist Final Secured

Gentek Tools Checklist TSV Final Secured

Gentek Tools Sheet Final Secured

  1. Oh DJ, Kim HJ, Chung CH. A study on mechanical properties of TiN, ZrN and WC coated film on the titanium alloy surface. The Journal of Korean Academy of Prosthodontics. 2006;44(6):740-50.
  2.   Ul-Hamid A. Synthesis, microstructural characterization and nanoindentation of Zr, Zr-nitride and Zr-carbonitride coatings deposited using magnetron sputtering. J Adv Res. 2020 Nov 25;29:107-119.
  3.   Grössner-Schreiber B, Griepentrog M, Haustein I, Müller WD, Lange KP, Briedigkeit H, Göbel UB. Plaque formation on surface modified dental implants. An in vitro study. Clin Oral Implants Res. 2001 Dec;12(6):543-51.
  4.   Groessner-Schreiber B, Hannig M, Dück A, Griepentrog M, Wenderoth DF. Do different implant surfaces exposed in the oral cavity of humans show different biofilm compo-sitions and activities?. European journal of oral sciences. 2004 Dec;112(6):516-22.
  5.   Grössner-Schreiber B, Teichmann J, Hannig M, Dörfer C, Wenderoth DF, Ott SJ. Modified implant surfaces show different biofilm compositions under in vivo conditions. Clin Oral Implants Res. 2009 Aug;20(8):817-26.
  6.   Brunello G, Brun P, Gardin C, Ferroni L, Bressan E, Meneghello R, Zavan B, Sivolella S. Biocompatibility and antibacterial properties of zirconium nitride coating on titanium abutments: An in vitro study. PLoS One. 2018 Jun 26;13(6):e0199591.
  7.   Zhurakivska K, Ciacci N, Troiano G, Caponio VC, Scrascia R, Pallecchi L, Lo Muzio L, Arena F. Nitride-Coated and Anodic-Oxidized Titanium Promote a Higher Fibroblast and Reduced Streptococcus gordonii Proliferation Compared to the Uncoated Titanium. Prosthesis. 2020 Dec;2(4):333-9.